Multi-user Analytical Lab

Instrumentation

Listed below are the current major instrumentation at MUAL.

Mass Spectrometers

Thermo Orbitrap Fusion™ Tribrid™ Mass Spectrometer
Thermo Orbitrap Fusion Tribrid Mass Spectrometer
  • Combines quadrupole, ion trap, and Orbitrap™ mass analysis in a revolutionary Tribrid architecture
  • Ultrahigh resolution up to 500,000 FWHM
  • Sub-1-ppm mass accuracy
  • Multiple dissociation techniques—CID, HCD, ETD
  • ID-X capability for small molecule analysis
  • Coupled to ESI and nano-ESI interfaces
    • UltiMate 3000 RS UHPLC & UltiMate 3000 RSLCnano
  • Primary applications: Global metabolomics, Proteomics, Characterization of unknowns

Thermo Orbitrap Exploris™ 120 Mass Spectrometer
Thermo Orbitrap Exploris 120 Mass Spectrometer
  • Quadrupole-orbitrap mass analyzer architecture allows for high resolution accurate mass MSn analysis
  • High resolution up to 120,000 FWHM (at m/z 200)
  • Sub-1 ppm mass accuracy, mass range m/z 40–3000
  • Equipped with PFAs-free tubing for PFAs analysis
  • Coupled to ESI interface
  • Vanquish binary pump UHPLC system
  • Primary applications: Characterization of unknowns, Semi-targeted small molecule analysis

Shimadzu LCMS-8040
Shimadzu LCMS-8040
  • Triple quadrupole mass spectrometer
  • Fast scan speeds with ultrafast polarity switching
  • 15,000 u/second with a 0.1 Dalton step width without loss of mass accuracy
  • Redesigned pseudo-quadrupole collision cell, allows for 1 msec pause times to eliminate crosstalk
  • Coupled to ESI interface
  • Primary applications: Targeted metabolomics, Quantitative analysis

Waters Xevo TQ Absolute
Waters Xevo TQ Absolute
  • Triple quadrupole mass spectrometer
  • Equipped with StepWave XS™ ion guide to enhance sensitivity and Xtended Dynamic Range (XDR) detector offers high sensitivity for negative ions.
  • Ultrafast scan speeds (20,000 Da/second) with rapid polarity switching, mass range m/z 2- 2048.
  • Coupled to ZSpray dual-orthogonal API sources ESI interface equipped with source shield to minimize contamination.
  • MRM tuning with ESI infusion for unmatched sensitivity.
  • Primary applications: Trace analysis, Targeted metabolomics, Quantitative analysis

Agilent 7250 GC/QTOF
Agilent 7250 GC/QTOF
  • Quadrupole Time-of-flight mass spectrometer
  • Delivers full-spectrum, high-resolution, accurate-mass data
  • Low-energy EI for softer ionization and molecular ion enhancement
  • Elucidates chemical structures with MS/MS capabilities
  • TOF mass accuracy- < 2ppm RMS
  • TOF Resolution > 25,000 at m/z 271.896
  • Data acquisition rates of up to 50 spectra per second
  • Electron Ionization, settable 5-200 eV
  • Primary applications: Metabolomics, Characterization & Quantitation of GC-amenable compounds

Agilent 5975C Series GC/MSD System
Agilent 5975C Series GC/MSD System
  • Single quadrupole mass spectrometer
  • Standard Electron Ionization
  • Triple-Axis Detector for superior sensitivity and spectral integrity
  • Coupled to a Pyroprobe 5150 Pyrolyzer
  • Capable of sampling solid samples
  • Ambient to 1400°C and programmable in 1°C increments
  • Cryofocusing to produces sharper peaks
  • Primary applications: Metabolomics, Quantitation of GC-amenable small molecules

 

Liquid Chromatographs

Ultra-High Pressure Liquid Chromatographs
Ultra-High Pressure Liquid Chromatographs
Ultra-High Pressure Liquid Chromatographs
Ultra-High Pressure Liquid Chromatographs
Ultra-High Pressure Liquid Chromatographs
  • Thermo UltiMate 3000 UPLC; Thermo UltiMate™ 3000 RSLCnano; Waters ACQUITY UPLC I-Class PLUS; Thermo Vanquish™
  • Coupled to mass spectrometers and diode-array and florescence detectors.

Shimadzu UFLCUltra-High Pressure Liquid Chromatographs
  • Shimadzu UFLC; Waters Acquity™ e λ PDA Detector
  • Photodiode-array and florescence detectors; capable of HPLC-UV/FL or HPLC-UV/FL-MS/MS analysis.

Gas Chromatographs

Gas Chromatographs
Waters DESI XS
Waters DESI XS
    • Shimadzu 2010 plus, Agilent 7890B, 7890A
    • Coupled to unit and high resolution mass spectrometers or a flame ionization detector

Imaging Sources

Waters DESI XS
Waters DESI XS
  • Desorption Electrospray Ionization (DESI) is a non-destructive sampling technique for analyzing the spatial distribution of small molecules at or near the surface of a sample.
  • Molecules are ionized with high performance solvent spray through a heated transfer line for efficient ionization.
  • Coupled to a triple quadrupole mass spectrometer, imaging data is collected from MS1, MRM, precursor ion, product ion, and SIM scans.